Text of this page, read by machine (may contain mistakes)
USER RAM
This is the area in CRAM that the cartridge programmer has chosen
to hold the ten byte song data areas which contain sound and
timing information to be processed by the OS sound routines.
These data aress Bust be stored as contiguous Blocks ef tan bytes
each. In all cases but one, the programmer may choose to “play”
a song in any data area; however, song @1 MUST use the FIRST song
gata area for the OF routines to work properly. Also, the byte
immediately following the last byte in the last Gata area MUST be
sero (this code tells the OS routine SND_MANACER to stop looking
for more song data areas; see bottom of page 5, Users’ Manual).
This byte will actomatically be set to sero by proper invocation
of the INIT_SOUND routine before any other OS sound routines are
called (see pages S and 13).
2) The ColecoVision OS entry point names of some of the sound
routines and dedicated locations are different from their names
Given in the Sound Users’ Manual. They are:
Entry Point Sound Vsers* Manuel
PLAY_IT JUKE_B0Or
SOUND_MAN BND_MANACER
SOUND_INIT INIT_SOUND
NOTES PTR_TO_LST_OF_SND_ADDRS
You should use the entry point names.
3) Page 22, last paragraph: It is mentioned that e special
effect routine may want to call the OS sound routines FREQ_SWEEP
and ATN_SWEEP to operate tpon data within the effect's data area,
which “require that data be ordered appropriately within & song
date area". This means:
Whether or not the special effect uses FREO_SWEEP or
ATN_SWEEP: bytes 3 and 4 (see FICURE 1) MUST contain the
frequency and attenuation dats as specified. This is
because PLAY_SONCS (called every interrupt) will output
For “REQ_SWEEP used by itself - in addition to bytes 3
and 4, bytes 5S, 6, and 7 must contain data as specified.
Bytes § and 9 may be used for whatever (since FREQ SWEEP
Goesn't look at them).
Tor ATN_SWEEP used by itself - in addition to bytes 3 and
4, bytes 5, 8, and ¥ pust contain data as specified.
Bytes 6 and 7 may be used for whatever (since ATN_SWEEP
doesn't look at them).
If Both FREOQ_SWEEP and ATN_SWEEP are used, all bytes in
the data area must Iook as specified in FICURE 1.