ADAM™ TECHNICAL REFERENCE MANUAL PRELTMINARY RELEASE CHAPTER 3 SOFTWARE ---------------------""---~..;_;_;_;~;__ 4. 1. 1 EOS Overwrite Addresses Some applications may not require all of the routines pro- vided by EOS. To accommodate this situation, EOS has three defined starting locations. Applications should always access the routines from the defined jump table locations. Location OD390H is the lowest EOS starting address. File manager software is located in this part of EOS. If the application program uses file manager software, the applica- tion should not overwrite OD390H or above. Location OEOOOH. If the application does not use the file manger software, it can overwrite EOS up to ODFFFH. Routines that access the lower level network device drivers, and the device drivers for the VDP, controllers and sound generator are available. Locations OF400H to OFC30H contain the lowest level device drivers for AdamNet. The application can extend up to OF3FFH if it is using OS 7 or its own drivers for the VDP, controllers and sound generator. 4. 1. 2 EOS Files The file structure takes advantage of the sequential design of the data pack. (For more information on tapes and tape formats, see Chapter 3, Section 5.) A file directory keeps track of the location of files on tape, and other pertinent information such as size, creation date, and protection attributes. Some programs, such as super games, do not require directories. Data is stored on tape in blocks of lK (1024 bytes). An EOS file occupies a number of contiguous blocks, allocated upon file creation. EOS files can be any number of blocks but; are limited by the physical storage space available. Block O is reserved for a cold start loader. Block 1 and up, depending on the directory size, contain the directory. The EOS file manager accesses and controls a file through a File Control Block (FCB) maintained in RAM. The FCB contains static and dynamic information about the file. The FCB is created when a file is opened and destroyed when the file is closed. Application programs are limited to two FCBs at any one time. Each FCB is 36 bytes long. A data buffer, 1024 bytes long, is associated with each FCB.

Menu